Contact - Conditions of sale - Links - Units converter - Impressum - Search

Rodent pincher - analgesia meter

Details

- Users -
- Publications -
- Technical specifications -
- Other products / accessories -  
  • UNIVERSITY OF MANITOBA Winnipeg, Canada
  • VERTEX PHARMACEUTICALS San Diego, USA
  • DUKE UNIVERSITY MEDICAL CENTER Durham, USA
  • MC MASTER UNIVERSITY Hamilton, Canada
  • PFIZER Sandwich, UK
  • INNSBRUCK MEDICAL UNIVERSITY Innsbruck, Austria
  • HARVARD MEDICAL SCHOOL Charlestown, USA
  • UNIL Lausanne, Switzerland
  • CENTRE HOSPITALIER ESQUIROL Limoges, France
  • CNRS UMR 7519 Strasbourg, France
  • ESCPI Paris, France
  • TROPHOS Marseille, France
  • INSERM U 788 Kremlin Bicêtre, France
  • INSTITUT FRANCOIS MAGENDIE Bordeaux, France
  • LABO DE PHYSIOLOGIE ET MANDUCATION Paris, France
  • PHARMALEADS Paris, France
  • SANOFI AVENTIS Vitry Sur Seine, Porcheville, Montpellier & Toulouse, France
  • CNRS, IPMC Valbonne, France
  • BIOCODEX Compiègne, France
  • INSTITUT PASTEUR Paris, France
  • CRSSA La Tronche, France
  • INSTITUT HENRY BEAUFOUR Les Ulis, France
  • PORSOLT AND PARTNERS Le Genest ST Isle, France
  • ASTRAZENECA R&D MONTREAL St Laurent, Canada
  • Poincaré plot descriptors of heart rate variability as markers of persistent pain expression in freely moving rats, by A. Charlet, J.-L. Rodeau, P. Poisbeau in Physiol. Behav. 104(5):694-701., October 2011
  • Modulation of astroglial glutamine synthetase activity affects nociceptive behaviour and central sensitization of medullary dorsal horn nociceptive neurons in a rat model of chronic pulpitis, by Y. Tsuboi, K. Iwata, J. O. Dostrovsky et al. in Eur J Neurosci., 34(2):292-302, July 2011
  • Targeting of sodium channel blockers into nociceptors to produce long-duration analgesia: a systematic study and review, by DP. Roberson, A.M. Binshtok, F. Blasl et al. in British Journal of PharmacologyVolume 164, Issue 1, pages 48–58, September 2011
  • Characterisation of sensory abnormalities observed in an animal model of multiple sclerosis: a behavioural and pharmacological study, by Thibault K., Calvino B., Pezet S. in European Journal of Pain, 15(3):231.e1-16., March 2011
  • Fast non-genomic effects of progesterone-derived neurosteroids on nociceptive thresholds and pain symptoms, by A.Charlet, F. Lasbennes, P.Darbon, P. Poisbeau in Pain, Vol 139-3 p.603. October 2008.
  • Combination of Mocrosurgery and Gene Therapy for Spinal Dorsal Root Injury Repair By S.Liu, B.Bohl, S.Blanchard, JBacci & al. In Molecular Therapy 992-1002. Feb 24 2009
  • Calibrated Forceps: A Sensitive and Reliable Tool for Pain and Analgesia Studies, by Luis-Delgado et al. in The Journal of pain, December 2005
  • Inflammatory Pain Upregulates Spinal Inhibition via Endogenous Neurosteroid Production, by P. Poisbeau et al. in The Journal of neuroscience, December 2005

Documents
Download PDF Download video Tell a friend



To order directly without requesting an estimate,
click here to download an order form
and fax it to (727)-520-0299.
A fast and accurate algometer based on an instrumented pincher as an alternative to the Randall-Selitto test: This new analgesia meter developed by Bioseb following Luis-Delgado et al. (2005) allows accurate nociceptive tests to measure mechanical pain threshold on rat or mouse limbs with minimal constraint.
    Presentation

     Changes of the nociceptive hind paw threshold induced by morphine Bioseb's "Rodent Pincher" algometer allows calibrated forceps to induce quantifiable mechanical stimulation in the animal (rats or mice) on a linear scale. The most suitable protocol was experimented by determining the effects of 3 repetitive measurements on the 2 hindpaws, respectively over long-term (9 days), mid-term (1 day) and short-term (2 hours). It was primarily developed as an analgesimeter/algometer (analgesia measurement instrument) for nociceptive tests. In this specific use, the Rodents Pincher not only represents an alternative to the "RANDALL & SELITTO" test - but also presents the following advantages when compared to the classical test:
    • More ethical handling, less stressful for the animal (rat or mouse) resulting in less variable measurements
    • Faster measurement, less traumatic for the tissues
    • Digital measurement with metrological traceability

    Furthermore, this pincher-based analgesia meter can also be used for other applications that require a controlled force or pressures values, for example :
    • Sensitivity recovery after nerve crush: pinching is applied at several places over the paw to see the sensitivity recovery
    • Mechanical injuries for thrombotic models
    • Mechanical stimulation for in vivo electrophysiological recordings using the possibility to trigger recording on force thresholds

    Comparative studies (including comparative tests with the Randall & Sellito analgesimeter) have demonstrated the accuracy of this pincher-based algometer for easy, fast and reproducible measurement of mechanical pain threshold on rat limbs. Moreover, it allowed to perform rat analagesia testing with minimal constraint, which reduces data variability.


    One of these experimental research works was carried out by the team of Prof. Poisbeau in the "Nociception & Pain" department of the "Institut des Neurosciences Cellulaires et Intégratives" (Université Louis pasteur) in Strasbourg.

    This work was described in two articles published in December 2005 in international reviews with a controlling committee:

    Validation method :
    Calibrated Forceps: A Sensitive and Reliable Tool for Pain and Analgesia Studies, by Luis-Delgado et al. in The Journal of pain, December 2005

    Scientific work :
    Inflammatory Pain Upregulates Spinal Inhibition via Endogenous Neurosteroid Production, by P. Poisbeau et al. in The Journal of neuroscience, December 2005

    Click on the title of one of the articles to send a request to download the PDF file

    Operating principle

    Bioseb's Rodent Pincher Analgesimeter: Embedded statistical computation Bioseb's Rodent Pincher Analgesimeter: Embedded statistical computation The pressure is applied in the "inter-digital" region. When used on the rat the pressure can also be applied to the tail. The instrument displays the force (in grams, newton, oz, lbs) at which the animal reacts and reports the nociception threshold.

    Individual pain threshold measurements (up to 100) are stored in the internal memory, and can be downloaded post experiment. Recently an embedded statistical computation has been included in the electronic device of the algometer. This is a very useful feature that as been very well received and used by users of large numbers of tests. The display shows in real time the mean, standard deviation and variation coefficient from groups of animals (rats or mice). This feature also allows the user to cancel any analgesia test incorrectly performed.

    Measured parameters

    The following parameters are measured by Bioseb's rodents pincher / analgesia instrument:
    • Maximum force applied as the animal reacts (movement, vocalization) (in grams, N, oz, lbs)
    • Duration of the test (using Bioseb's BIO-CIS software) in seconds

    Research applications

    Bioseb's Rodent Pincher Algometer can be used for a variety of research on nociception and analgesia, including:
    • In vivo models evaluation of pain
    • Mechanisms related to mechanical nociception
    • Whenever a calibrated force is necessary

    Bioseb's new pincher design: mounting of custom-made bits to suit your most specific needs and analgesia applications Built-in components

    These built-in components will make the analgesia measurement easier:
    • Desktop stand for easy reading
    • Footswitch to reset the zero of the rodent pincher analgesimeter while keeping hands free.
    • RS232 output to transfer displayed data to a PC.
    • Our new pincher design allows the mounting of custom-made bits to suit your most specific needs and applications. Please contact us if you have any special request about the pincher, and we'll do our best to cover your needs.

    Options:

    • Our optional RSIC software for Windows sends directly the displayed values in an Excel (MS) sheet. This allows the user direct access to a ready report and options for further analysis, without any re-copy error. Supplied with an RS232 cable.
    • External pod to display a led light or produce a sound when reaching a preset threshold of force.
    • Analog output and cable
    • TTL output
    • Additional sensor tests : our Electronic Von Frey probe, Small Animal Algometer come with their own calibration modules that are recognized by the electronic unit.

    Supplied with:

    • Bench control unit (batteries and main power supply)
    • One rat or mice pincher, capacity 2000 grs
    • Carrying case
    • Footswitch for zeroing the force and having the hands "free"
    • RS232 output
    • User manual

THE INFORMATION IN THIS WEB SITE AND IN LINKED PAGES AND DOCUMENTS IS PROVIDED "AS IS" AND DOES NOT CREATE ANY EXPRESS OR IMPLIED WARRANTY ABOUT EB-INSTRUMENTS OR ITS PRODUCTS OR SERVICES.

Information published on this Web Site as well as services, product specifications, availability and prices are subject to change without notice. EB-INSTRUMENTS may also make improvements and/or changes in the products and/or the programs described in this Web Site at any time without notice.

EB-INSTRUMENTS has made reasonable efforts to verify that the information in this Web site was accurate when first published. Such information may contain errors or omissions, however, and it is subject to change without notice. EB-INSTRUMENTS does not undertake to update this information to include any such changes or to correct errors or omissions. EB-INSTRUMENTS assumes no responsibility for any use of the information in this Web site or for any infringement of patents or other rights of third parties that may result. Certain information may be country-specific and may not apply in all countries.

Animal Rat or mouse (2 different pinchers)
Measuring Range 0 to 2000 grams
Units Grams / newtons
Resolution 0,1 gram or 0,001 N
Results Displays the current applied force and the maximum applied force during the test
Statistic Mean, standard deviation and variation coefficient
Power supply Battery powered, this instrument is autonomous.
Possibility of using a 220V/110V 50hz/60hz adapter.
Data output RS232 for PC or printer
EMC Controlled

Model: Model:
BIO-RPR
Rodent pincher - analgesia meter
For rats Contact us

Linked products:
BIO-EVF3
Electronic Von Frey
Contact us
SMALGO-CT
SMALGO : SMall animal ALGOmeter
Contact us
BIO-RPM
Rodent pincher - analgesia meter
For mice Contact us
Information request

Please fill up this form, and our team will contact you as soon as possible with the requested information about our Rodent pincher - analgesia meter

Your e-mail address:


Type of information requested:


EB-Instruments - PO Box 2156 - Pinellas Park, FL, 33780 - Phone :(727)521-1808 - Fax : (727)-520-0299 - E-Mail :info@eb-instruments.com